Internet explorer 录制Siebel VUgen脚本

Internet explorer 录制Siebel VUgen脚本,internet-explorer,recording,loadrunner,siebel,Internet Explorer,Recording,Loadrunner,Siebel,我在录制VUGen脚本时遇到两个问题。 我的配置: [WinInet Request ( 86c: 8cc)] GET "https://bcvm168/fins_rus/files/main.css" [WinInet Request ( 86c: 8cc)] GET "https://bcvm168/fins_rus/23016/scripts/login.js" [WinInet Request ( 86c: 8cc)] GET https://bcvm168/fins_rus/23

我在录制VUGen脚本时遇到两个问题。 我的配置:

[WinInet Request  ( 86c: 8cc)] GET "https://bcvm168/fins_rus/files/main.css"
[WinInet Request  ( 86c: 8cc)] GET "https://bcvm168/fins_rus/23016/scripts/login.js"
[WinInet Request  ( 86c: 8cc)] GET https://bcvm168/fins_rus/23016/scripts/swecommon_top.js
  • 负载转轮11.00
  • Internet Explorer 8.0.6001.18702
  • Windows XP Professional SP 3,I5-2500K CPU@3.30 GHz,2.91 Gb RAM
  • 我使用Siebel–web协议。我们的应用程序使用https协议

    VUGen Recording options  are:
    General-Script:
    Generate think time greater than threshold = 3, checked
    Track processes created as COM local servers
    General – Protocols:
        Siebel –Web
    General – Recording:
        HTML-based script
            Advanced- Script type = A script containing explicit URLs only
            Advanced – Non HTML generated elements =Do not record
    Network
        Port Mapping
            Capture level = WinINET level data
    HTTP Properties – Advanced
        Save snapshot resources locally checked
        Support charset = UTF-8 
    HTTP Properties –Correlation
        Siebel correlation checked
    
    第一个问题是: 在我的主机上录制脚本时,有很多事件(仅登录时大约有800个)。我将它与我的虚拟机和coleagues主机进行比较

    这是我的主机的示例:

    [Network Analyzer ( bf8:1714)] ------------------------------------------------------------------------------------------
    [Network Analyzer ( bf8:1714)] Load Network Traffic Analyzers:
    [Network Analyzer ( bf8:1714)]     Analyzer Module: Siebel_Web (value=)
    [Network Analyzer ( bf8:1714)]     Analyzer Module: local_server (value=)
    [Network Analyzer ( bf8:1714)] ------------------------------------------------------------------------------------------
    [Network Analyzer ( bf8:1158)] Address lookup for wks03 = 172.31.86.25
    [Network Analyzer ( bf8:1738)] Address lookup for wks03 = 172.31.86.25
    [Network Analyzer ( bf8:1738)] Request Connection: Remote Server @ 192.168……..   (Service=)  (Sid=  1)  PROXIED!
    [Network Analyzer ( bf8:1158)]   (Sid:  1) Client -> Server : 77 bytes 
    [Network Analyzer ( bf8:1158)]   (Sid:  1) Server -> Client : 1380 bytes 
    [Network Analyzer ( bf8:1158)]   (Sid:  1) Server -> Client : 66 bytes 
    [Network Analyzer ( bf8:1158)]   (Sid:  1) Client -> Server : 182 bytes 
    [Network Analyzer ( bf8:1158)]   (Sid:  1) Server -> Client : 43 bytes 
    [Network Analyzer ( bf8:1158)]   (Sid:  1) Client -> Server : 325 bytes 
    [Network Analyzer ( bf8:1158)]   (Sid:  1) Server -> Client : 377 bytes 
    [Network Analyzer ( bf8:1158)]   (Sid:  1) Client -> Server : 328 bytes 
    [Network Analyzer ( bf8:1158)]   (Sid:  1) Server -> Client : 1746 bytes 
    [WinInet Request  ( bf8: d08)] GET "https://bcvm168/fins_rus"
    [Network Analyzer ( bf8:1158)]   (Sid:  1) Client -> Server : 626 bytes 
    [Network Analyzer ( bf8:1158)]   (Sid:  1) Server -> Client : 642 bytes 
    [Network Analyzer ( bf8:1158)]   (Sid:  1) Server -> Client : 2020 bytes 
    [WinInet Request  ( bf8: d08)] GET "https://bcvm168/fins_rus/start.swe?SWECmd=Start&SWEHo=bcvm168"
    
    这是我的虚拟机示例:

    [WinInet Request  ( 86c: 8cc)] GET "https://bcvm168/fins_rus/files/main.css"
    [WinInet Request  ( 86c: 8cc)] GET "https://bcvm168/fins_rus/23016/scripts/login.js"
    [WinInet Request  ( 86c: 8cc)] GET https://bcvm168/fins_rus/23016/scripts/swecommon_top.js
    
    我不知道如何关闭此网络分析仪。

    第二个问题是记录深入操作的问题:

    • 我正在尝试使用portmapping=wininet记录向下搜索 这一尝试失败了:记录了大量事件(大约3000个),在此之后IE选项卡恢复,没有其他记录
    • 当我尝试使用端口映射套接字时,向下搜索并没有失败,但没有任何记录。 请帮帮我
    我认为,当您要求关闭产品记录功能的核心项目时,您需要一位导师在本地为您提供帮助。这意味着你已经被甩到这个角色上,几乎没有关于你所使用工具的培训


    如果上面的观察是正确的,你被要求在没有工具、过程或导师的情况下交付一段时间,这可能长达一年(取决于你的基础技能),那么你应该意识到这条路径几乎有100%的失败率,你的管理者应该为你的困境负责。p> 您能在您的机器上手动遍历流程吗? 如果没有,请检查- 所有与sieble相关的高交互对象都加载了IE。 C:\Windows\下载的程序文件

    URL作为受信任的站点添加到IE中。(Internet选项-安全选项卡) plus-启用activeX控件和插件(Internet选项-安全选项卡-自定义级别)

    更改LR中的记录设置- Portmapping=套接字级数据


    希望这有帮助

    嗯,一些实践经验给了我一种“欺骗方式”。在尝试录制脚本时,通过在不同的Windows进程之间切换来解决此问题。例如,如果在我录制按钮单击时应用程序兑现,我会单击它并使用应用程序最小化窗口,10-20秒后,该步骤将被录制。

    James,感谢您的重播,我的导师也会帮助我,但我更愿意尝试多种方法来解决我的问题。您有什么实用的建议吗?请使用HP提供的资料,与HP认证的讲师一起参加正式的产品培训!我在发布这个问题之前已经做过这个选项,因为它是siebel工作的标准设置。不幸的是,它仍然不能工作。即使是hp lr11.00补丁也没有帮助…感谢您的重播。也许你还有别的想法?